LCM4000HV
4000 Watts Bulk Front End Centralized Power for LED Horticulture
Advanced Energy’s Artesyn LCM4000HV series and associated LCM12K mounting shelf has been designed specifically to provide a centralized current source for medium to large scale LED lighting and horticulture applications. The unique input design allows all standard AC inputs 208 VAC to 600 VAC
from single to 3 phase sources. The output of each 4 kW block provides flicker free current source from 0 to 16 A at an output voltage range between 100 VDC to 300 VDC. High nominal operating voltage provides the benefits of lower cost standard wiring and higher efficiency with minimal voltage drop over long
distance.
The convenient 19” 1U rack mount shelf is designed for hot plug replacement of the 4 kW modules insuring the highest reliability and simplest maintenance possible. For large systems stacking 10 shelves in a short 10U cabinet would provide 120 kW for a normal sized grow area.
- Specifications
- Special Features
- Models - Stock check
-
Total Max Power:
4,000 W -
Total Max Current:
16 A -
Input Voltage:
187 V to 528 V -
Output Voltage:
100 V to 300 V -
Outputs:
Single -
Size (L x W x H):
18.860" x 5.510" x 1.590" -
Warranty:
5 years -
Operating Temperature:
0 Deg C to 50 Dec C
Electrical Specifications
- Input
- Output
- Logic Control
- Isolation
- Other
- Input Range: 187-264 VAC; 311-528 VAC
- Input Frequency: 47 to 63 Hz, Nominal 50/60 Hz
- Input Fusing: Both Lines Fused
- Inrush Current: <60A Peak at 264/528 VAC
- Power Factor: 0.98 @ 100% load, at 208VAC
- Harmonics: Meets IEC 61000-3-12 Requirements
- Input Current: 25A max at 180 VAC
- No Load Power: 35W max at 180 VAC
- Efficiency: up to 95.2%
- Leakage Current: < 5mA @ 264/528 VAC, 60 Hz
- Output Rise Time: 80 mSec max
- Hold-up: 10 mSec min
- Nominal Output Voltage: 250 VDC
- Maximum Output Current: 16.0 Amps
- Maximum Output Power: 4000 W
- Output Adjust Range: 100 VDC to 300 VDC
- Output Voltage Adjustment Accuracy: +/-0.5% on Nominal (Digital); +/-1% (Analog)
- Output Static Regulation: 0.5% Line, 0.75% load (of nominal)
- Line Transient/Load Transient: +/-3%, +/-5% of nominal
- Ripple % Noise (P-P): 0.5% of Nominal
- Max Output Capacitance: 600 uF
- Digital Communication: MODBus
- Analog Control: 0-10VDC; 0-24VDC
- Primary to PE: 4000 VDC
- Primary to Secondary: 4000 VDC
- Secondary to PE: 3200 VDC
- Primary to User-Accessible: 6000 VDC
- Secondary to User-Accessible: 5000 VDC
- Modules per Shelf: 3 max
- Voltage Range Setting: Parallel or Serial (Customer Configurable)
- Wide input voltage range
- Single or 3 Phase
- 4000 W output power
- Low cost
- 480 mm x 140 mm x 40.3 mm
- 38 Watts per cubic inch
- Industrial safety
- High efficiency: up to 94%
- Variable speed “Smart Fans”
- Dust control for fan cooling
- DSP controlled
- Digital and analog communication
- Scales easily (Module/Shelf/Rack)
- Meets DLC 2.1 requirements
- Supports Artesyn iTS and IHLC
- Five-year warranty